The most mainstream speed regulation method of the double speed chain is to adjust the speed of the driving motor through a frequency converter, and with the calibration of the mechanical structure, it can achieve precise and controllable speed of the tooling board, fully adapting to the production rhythm of different workstations.
1、 Mainstream speed regulation method
Variable frequency stepless speed regulation: This is the most commonly used solution on site, which adjusts the output frequency of the frequency converter to change the motor speed, continuously variable throughout the process, without the need to modify the mechanical structure, and is suitable for flexible production lines of multiple varieties.
Reducer speed ratio speed regulation: It belongs to graded speed regulation. By replacing reducers with different reduction ratios, the line speed can be fixed and adjusted. It is suitable for standardized production lines with long-term stable rhythm, high stability, and low transformation cost.
Fine adjustment of sprocket diameter: When the parameters of the motor and reducer are fixed, replacing the active sprocket with different diameters can adjust the linear speed in a small range, which is suitable for small speed calibration on site.
Intelligent linkage speed regulation: relying on PLC and photoelectric sensors, it can achieve segmented automatic transmission, automatic speed reduction at the assembly station, and automatic speed increase at the transfer section, which is a standard solution for modern lean production lines.
2、 On site practical speed control steps
No load basic debugging: Remove all tooling boards, start the frequency converter from a low frequency of 5-10Hz, observe whether there is any abnormal noise or deviation in the chain and motor, confirm that there is no jamming, and gradually increase the frequency.
Full load debugging: Place a full load fixture board with workpieces, simulate real production conditions, observe for chain jumping and roller slippage, and run for 2 minutes after each increase of 5Hz to confirm the status.
Actual calibration speed: Mark a distance of 10 meters, use a stopwatch to measure the passage time of the fixture board, calculate the actual linear speed, and adjust the frequency of the frequency converter according to the process requirements.
Match workstation rhythm: Adjust the speed to ensure that the fixture board contacts the stopper buffer and stops smoothly without obvious impact rebound, while ensuring that there is no accumulation of workpieces waiting at each workstation.
Multi segment line calibration: For long-distance segmented drive lines, it is necessary to ensure that the speed deviation of each segment is controlled within ± 5% to avoid the fixture board squeezing and jamming at the docking point.
Parameter locking archiving: After debugging is completed, lock the parameters of the frequency converter, record the current frequency and actual line speed, and prevent on-site personnel from making changes due to misoperation.
3、 Safe speed regulation range with different multiple speed ratios
2.5 times speed chain: The conventional applicable frequency is 20-40Hz, corresponding to a tooling board line speed of 6-12m/min. The recommended starting debugging frequency is 15-20Hz.
3x speed chain: The standard applicable frequency is 15-30Hz, corresponding to a line speed of 7-11m/min for the tooling board. The operating frequency must not exceed 35Hz to avoid damage to the blocker due to excessive impact kinetic energy of the tooling board.
4、 Key points for speed regulation and pit avoidance
Do not directly set the frequency converter to operate at full frequency of 50Hz. Long term high-speed operation will increase the wear rate of chains, rollers, and buffer blocks by 40% -60%, significantly increasing maintenance costs in the later stage.
If there is a collision or rebound of the fixture board after speed regulation, priority should be given to lowering the frequency of the inverter, rather than simply adjusting the air pressure of the blocker to counteract the impact.
Do not frequently adjust the speed back and forth significantly. Frequent motor speed changes will increase electrical component losses. After the process is fixed, try to lock the parameters as much as possible.
It is recommended to set the acceleration time to at least 5 seconds and the deceleration time to at least 8 seconds to avoid chain tooth jumping and workpiece slippage caused by sudden start stop.